ENERGY STAR gives retrofit targets for attics by climate zone. For an uninsulated attic the targets are R-30 in zone 1, R-49 in zones 2–3 and R-60 in zones 4 through 8. If the attic already has 3–4 inches of insulation, the targets are R-25 (zone 1), R-38 (zones 2–3) and R-49 (zones 4–8). These are total R-values for existing wood-framed homes, not a building-code ruling, so check local code too.
How the thickness is calculated
R-value is thickness divided by thermal conductivity, and R-values of layers in series add up. The U-factor is the reciprocal of R (U = 1 ÷ R). So thickness needed = (target R − existing R) ÷ R per inch.
Example: a 1,000 ft² attic in zone 2–3, uninsulated (target R-49, existing R-0), fiberglass at an example R-3.2 per inch needs 49 ÷ 3.2 = 15.3 inches. At 40 ft² per package that is 25 packages; at an example $45 each, about $1,125.
Choosing a material
Fiberglass and mineral wool batts or loose-fill: low cost per R, but only as good as the installation. Gaps and compression lower the real R-value.
Rigid foam (EPS, XPS, polyiso): more R per inch, useful where depth is limited. Foam boards are normally cut and sealed at the edges.
Read the label: the R-per-inch figures here are example values. Use the R-value and coverage printed on the product you buy.
Before you add insulation
Air-seal gaps around wiring, chimneys and attic hatches first, and keep vents and recessed-light clearances clear. The calculator covers the insulation layer only, not air leaks, moisture or ventilation. For the bigger picture see home energy audit and appliance energy use.
ENERGY STAR targets for an uninsulated attic are R-30 in zone 1, R-49 in zones 2–3 and R-60 in zones 4–8. With 3–4 inches already there, they are R-25, R-38 and R-49.
How many inches of insulation is R-49?
It depends on the material. At an example R-3.2 per inch for fiberglass, R-49 is about 15.3 inches (49 ÷ 3.2). Foam boards need fewer inches because they have more R per inch.
What is the difference between R-value and U-factor?
R-value measures resistance to heat flow, so higher is better. U-factor is its reciprocal (1 ÷ R), so lower is better. R-49 corresponds to U ≈ 0.0204 BTU/h·ft²·°F for the insulation layer.
Can I add new insulation on top of old insulation?
Usually yes, because R-values of layers in series add up. Enter the old insulation’s R-value as “already in place” and the tool shows how much more to add. Check that the old material is dry and not compressed.
Do R-values per inch on this page come from a standard?
No. They are example values for planning. Always use the R-value printed on the product label and the manufacturer’s coverage chart.